The Stand Alone Degassers are designed for use alongside your fluidic system. Simply plug in the unit and route your fluids through the degasser for consistent gas free fluids.

Inquiry Now

Overview

Features

Specifications

The Idex Full Stand Alone Degassing System is a plug-and-play solution for ensuring consistent, gas-free fluids in fluidic systems, providing reliable degassing without requiring external pumps.

Key Features

  • Simple plug-and-play design for easy integration.
  • Ensures consistent, gas-free fluid handling.
  • Suitable for use in various fluidic applications.

Available Models

Technical Specifications 

Length (in)10.35
Pressure Rating Max (psi)70
Tubing ID (in)0.045
Tubing ID (mm)1.143
Power Requirements100-240V AC 1A 50 to 60hz
Recommended Flow Rate (ml/min)2
Membrane TypeTeflon™ AF
Internal Volume Per Channel uL480
Wetted MaterialsTeflon™ AF, Teflon™ FEP, PEEK and Glass-filled PPS (Polyphenylene Sulfide)
Vacuum Flow Path Materials303 Stainless Steel, Polypropylene, PTFE, EPDM Rubber
Liquid Connections¼-28 UNF
Expected Lifetime>5 years (continuous run @ 60 RPM)
Width (in)2.87
Height (in)5.17

Stand Alone Vacuum Degasser Systems are specifically designed for HPLC. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 2-5 channel systems at analytical flow rates and preparative up to 40mL/min. Select the “GPC” version for applications using hexanes.

  • Analytical Stand Alone Degasser, 2 Channels
  • Analytical Stand Alone Degasser, 3 Channels
  • Analytical Stand Alone Degasser, 4 Channels
  • Analytical Stand Alone Degasser, 5 Channels
     

Technical Specifications 

Length (in)10.35
Tubing ID (in)0.045
Tubing ID (mm)1.143
Power Requirements100-240V AC 1A 50 to 60hz
Recommended Flow Rate (ml/min)2
Membrane TypeTeflon™ AF
Internal Volume Per Channel uL480
Wetted MaterialsTeflon™ AF, Teflon™ FEP, PEEK and Glass-filled PPS (Polyphenylene Sulfide), Stainless Steel
Vacuum Flow Path Materials303 Stainless Steel, Polypropylene, PTFE, EPDM Rubber
Liquid Connections¼-28 UNF
Expected Lifetime>5 years (continuous run @ 60 RPM)
Width (in)2.87
Height (in)5.17

Stand Alone Vacuum Degasser Systems are specifically designed for HPLC. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 2-5 channel systems at analytical flow rates and preparative up to 40mL/min. Select the “GPC” version for applications using hexanes.

  • Analytical GPC Stand Alone Degasser, 2 Channels, GPC
  • Analytical GPC Stand Alone Degasser, 3 Channels, GPC
  • Analytical GPC Stand Alone Degasser, 4 Channels, GPC

Technical Specifications 

Length (in)10.35
Pressure Rating Max (psi)70
Tubing ID (in)0.075
Power Requirements100-240V AC 1A 50 to 60hz
Membrane TypeTeflon™ AF
Wetted MaterialsTeflon™ AF, Teflon™ FEP, PEEK and Glass-filled PPS (Polyphenylene Sulfide)
Vacuum Flow Path Materials303 Stainless Steel, Polypropylene, PTFE, EPDM Rubber
Liquid Connections¼-28 UNF
Expected Lifetime>5 years (continuous run @ 60 RPM)
Width (in)2.87
Height (in)5.17

Stand alone Vacuum Degasser Systems are specifically designed for HPLC. The Preparative systems are designed for flow rates up to 40ml/min. The system removes dissolved gases from the mobile phases to reduce retention time shifts and improve baseline stability. Removing dissolved gasses eliminates bubbles before they occur and removes oxygen which can interfere with UV detection methods. The system is available in 2-5 channel systems at analytical flow rates and preparative up to 40mL/min. Select the “GPC” version for applications using hexanes.

  • Preparative Stand Alone Degasser, 2 Channels, Prep, Recommended Flow Rate 20mL/min, Internal Volume 8.4 mL
  • Preparative Stand Alone Degasser, 2 Channels, Prep, Recommended Flow Rate 40mL/min, Internal Volume 13.8mL

Key Industries

  • Biopharmaceutical and Biotechnology
  • Chemical
  • Cosmetics & Personal Care
  • Education & Academics
  • Food & Beverage
  • Medical
  • Oil & Gas
  • Pharmaceutical
  • Powders & Pigments / Coating

More Products

IDEX Health & Science

IDEX Health & Science is the global authority in fluidics and optics, bringing life to advanced optofluidic technologies with our…

    • MALAYSIA

      DKSH Technology Sdn. Bhd.
      B-11-01, The Ascent, Paradigm, No. 1,
      Jalan SS7/26A, Kelana Jaya
      47301 Petaling Jaya, Selangor
      Malaysia

      +60 3 7882 8711

      Contact Now

    • SINGAPORE

      DKSH Singapore Pte Ltd
      625 Lorong 4 Toa Payoh, #03-00
      319519 Singapore
      Singapore

      +65 6962 3121

      Contact Now

    test block for Laos

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Your download – just a few steps away

    Please enter your details here:

    test

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us

    Contact us