Binder – Constant Climate Chambers – Series KBF P – With ICH-Compliant Light Source

The KBF P constant climate chamber, equipped with ICH-compliant light source, is an expert when it comes to photostability tests and ensures clear test results in accordance with ICH Guideline Q1B. At the same time, the variable-position illumination cassettes offer homogeneous lighting conditions.

Key Features

  • Homogeneous climate conditions thanks to APT.line™ technology
  • Automatic water and wastewater management
  • Pressure humidification with fast response times
  • Variable position and removable illumination cassettes
  • ICH-compliant illumination for long-term stable test conditions

 

Inquiry Now

Overview

Features

Specifications

Humidity Test Chambers With ICH-Compliant Light Source

BINDER is a supplier of state-of-the-art Humidity test chambers. In its KBF-P series, BINDER has developed Humidity test chambers with ICH-compliant light source, which combine high performance and versatile functionality with compliance with standards.

KBF-P Humidity test chambers have been designed specifically for photostability testing, providing an all-round solution in a single chamber you can rely on.

Humidity Test Chambers With Unique Light Concept

Complete with ICH-compliant light source, the BINDER Humidity test chambers in the KBF-P series comply with ICH Guideline Q1B, Option 2. They feature height-adjustable illumination cassettes and, thanks to the patented Synergy Light system, homogeneous light distribution over the entire usable area. The patented APT.line™ preheating chamber technology, meanwhile, ensures optimum homogeneous temperature conditions. Humidity is regulated using a capacitive humidity sensor and steam humidification. These climate chambers can be used within a temperature range of between 0 °C and 70 °C, or between 10 °C and 60 °C with light. They operate within a humidity range of between 10% RH and 80% RH.

With their unique light concept, precise climate conditions, and quick, accurate illumination, BINDER Humidity test chambers with ICH-compliant light source deliver the best results. The high levels of performance and functionality offered by these Humidity test chambers from BINDER are combined with ease of handling and a durable, robust quality.

Technical Specifications

ModelHousing dimensions not incl. fittings and connections
W x H x D
Internal dimension 
W x H x D
Net weightInterior volume
KBF P 240925 x 1460 x 800 mm650 x 785 x 485 mm213 kg247 L
KBF P 7201250 x 1925 x 890 mm973 x 1250 x 576 mm374 kg700 L

Available Models

  • Temperature range: 0 °C to 70 °C
  • Temperature range with light: 10 °C to 60 °C
  • Humidity range: 10 % to 80 % RH
  • 2 positionable illumination cassettes with ICH-compliant UV/Vis light source
  • APT.line™ preheating chamber technology
  • Humidity regulation with capacitive humidity sensor and vapor humidification
  • Inner chamber made of stainless steel
  • BINDER Multi Management Software APT-COM™ Basic Edition
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Internal data logger, measured values can be read out in open format via USB
  • Unit self-test for comprehensive status analysis
  • Tight-sealing inner door made of safety glass (ESG)
  • Avoidance of glass corrosion by special TIMELESS coating
  • 2 stainless steel racks
  • Access port with silicone plug, 30 mm, left
  • 4 stable castors, two with brakes
  • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
  • Computer interface: Ethernet
  • Door heating
  • Temperature range: 0 °C to 70 °C
  • Temperature range with light: 10 °C to 60 °C
  • Humidity range: 10 % to 80 % RH
  • 3 positionable illumination cassettes with ICH-compliant UV/Vis light source
  • APT.line™ preheating chamber technology
  • Humidity regulation with capacitive humidity sensor and vapor humidification
  • Inner chamber made of stainless steel
  • BINDER Multi Management Software APT-COM™ Basic Edition
  • Intuitive touchscreen controller with time-segment and real-time programming
  • Internal data logger, measured values can be read out in open format via USB
  • Unit self-test for comprehensive status analysis
  • Tight-sealing inner door made of safety glass (ESG)
  • Avoidance of glass corrosion by special TIMELESS coating
  • 3 stainless steel racks
  • Access port with silicone plug, 30 mm, left
  • 4 stable castors, two with brakes
  • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
  • Computer interface: Ethernet
  • Door heating

BINDER Constant Climate Chambers

The Pilz in Tropical Climate Zone IV

Key Industries

  • Education & Academics
  • Food & Beverage
  • Pharmaceutical
  • Service

More Products

Binder

With 22,000 series production machines supplied each year globally, family company BINDER is now one of the leading experts on…

  • KBF P series Brochure – Binder


  • INDONESIA

    PT. DKSH Market Expansion Services Indonesia
    AIA Central 39th floor. Jalan Jenderal Sudirman Kavling 48A
    12930 Jakarta Selatan
    Indonesia

    +62 21 2988 8557

    Contact Now

  • AUSTRALIA

    DKSH Australia Pty Ltd
    1 Beyer Road
    3195 Braeside VIC
    Australia

    1800 010 114

    Contact Now

  • CAMBODIA

    DKSH (Cambodia) Ltd
    Corner Preah Monivong Boulevard and Street 484
    Phnom Penh
    Cambodia

    +855 87 887 883

    Contact Now

  • KOREA

    DKSH Korea Ltd.
    3rd Floor, Zen building, 152 Dogok-ro, Gangnam-gu
    06261 Seoul
    Korea

    +82 2 2192 9723

    Contact Now

  • LAOS

    DKSH Laos Company Ltd.
    3rd Floor, Vientiane Center Office Building Khouvieng Road, Sisattanak District
    Vientiane Capital
    Laos

    +856 21 221 023

    Contact Now

  • MYANMAR

    DKSH (Myanmar) Ltd.
    Thitsar Road, Yankin Township
    Yangon
    Myanmar

    +951 8565270

    Contact Now

  • NEW ZEALAND

    DKSH New Zealand Limited
    33 Westpoint Drive
    0618 Hobsonville, Auckland
    New Zealand

    0800 951 010

    Contact Now

  • THAILAND

    DKSH Technology Limited (Head Office)
    2533 Sukhumvit Road, Bangchak, Phrakhanong
    10260 Bangkok
    Thailand

    +66 2 639 7000

    Contact Now

  • VIETNAM

    DKSH Technology
    16th Floor, Peakview Tower. 36 Hoang Cau Street,
    O Cho Dua Ward, Dong Da District
    10000 Ha Noi
    Vietnam

    +84 24 3942 4725

    Contact Now

test block for Laos

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Your download – just a few steps away

Please enter your details here:

test

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us