Skalar – TOC & TN Analyzer for Solid & Liquid Sample – Primacs Series

  • AUSTRALIA

    DKSH Australia Pty. Ltd.
    1 Beyer Road
    3195 Braeside VIC
    Australia

    1800 010 114 (hotline)

    Email

  • THAILAND

    DKSH Technology Limited (Head Office)
    2533 Sukhumvit Road, Bangchak, Phrakhanong
    10260 Bangkok
    Thailand

    +66 2 639 7000

    Email

The PrimacsSERIES provides fast, reliable, accurate, and low-level analysis of Total Nitrogen / Protein, Total Carbon, Total Organic Carbon, Total Elemental Carbon, and Total Inorganic Carbon all in one unit.

The measurement of TC, TOC, TEC, and TIC is based on high-temperature catalytic combustion with Non-Dispersive Infrared detection (NDIR). The temperature settings are variable and a special temperature ramping program allows the analysis of TEC, according to DIN 19539. The TN/Protein analysis is based upon DUMAS methodology and detection with Thermal Conductivity (TCD). TIC can also be determined separately using automatic acidification and purging. All systems come with a practical and flexible software package, with pre-installed method files, user-definable sample table set up, integrated QC features, etc.

The analyzer contains a large integrated 100 position autosampler with a unique vertical sample introduction system. The sample ashes remain in the crucible after the analysis and are taken out to the instrument with the removal of the crucible. This avoids sample ash build-up in the combustion zone and therefore reduces maintenance.

Technical Specifications

SNC-100
Measuring range0.02-200mg C abs
Analysis timeApprox. 3-5min for TC/TN or TIC
Sample sizeSolid: up to 3g
Liquid: up to 1000mg (uL)
Furnace temperatureCombustion oven 1200 °C
2-Zone Oxidation/Reduction oven 750/600 °C
TIC reactor at 150 °C
SoftwareSN-Access
Carrier gasHelium gas supply (99.995%)
Combustion gasOxygen gas supply (99.995%)
Power requirements220-240V 50-60Hz
Weight120kg approx.

Key Features

Primacs Series

  • Analytes TC, TOC, TEC, TIC, TN / Protein
  • Suitable for solid samples and liquid samples
  • 100 position autosampler
  • Sample weights up to 3 grams
  • Automatic balance interfacing
  • Reusable ceramic sample crucibles
  • High temperature combustion with NDIR detection (Carbon)
  • Dumas methodology and TCD detection (Nitrogen) environmental friendly alternative for Kjeldahl determination
  • Range 0.02 – 100 mg N (abs.)
  • Range 0.01 – 200 mg C (abs.)
  • Methods according CEN, ISO 10694, NEN-EN 131137, AOAC 990.03, AOAC 992.15, AACC 46-30, ASBC, DIN 19539

Primacs SNC100 Carbon Nitrogen Analyzer

Key Industries

  • Environmental
  • Food & Beverage
  • Pharmaceutical

Brand

Skalar

Skalar, the world leader in wet chemistry technology, offers over 300 proven applications utilizing various combinations of automatic dilutions, additions, mixing, heating, dialysis, extractions, distillation, digestion, phase-separation, hydrolysis, ion-exchange/reduction and more. Skalar has developed a proven systematic approach to provide a quality system starting with complete applications engineered on customer samples to provide the best possible configuration to the customer needs and requirements, training and installation by qualified specialists and complete application and service support.

Similar Products

test block for Laos

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Your download – just a few steps away

Please enter your details here:

test

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us