SI Analytics – Titrator TitroLine® 7500 KF Module With 20 ml Exchangeable Head
The TitroLine® 7500 KF is the universalist for the volumetric Karl Fischer titration with a wide operating range of a few ppm – 100% water content. The addition of the solvent and the extraction of the titrated sample are carried out by the titration stand TM 235 KF at the push of a button.
General Features
- High visibility, full color display that can be easily viewed from a distance and at extreme angles.
- Reagent data is securely stored in the intelligent and interchangeable modules
- Includes up to three USB, one LAN and two RS232 ports for expansion and connection of devices
- Export the results as PDF or CSV, also to networks.
Technical Specifications
SI Analytics Titrator TitroLine® 7500 KF module with 5 ml exchangeable head | SI Analytics Titrator TitroLine® 7500 KF module with 10 ml exchangeable head | SI Analytics Titrator TitroLine® 7500 KF module with 20 ml exchangeable head | |
---|---|---|---|
Measuring input µA/KF | μA-connector for double platinum electrodes, connection: 2 x 4 mm – sockets), polarisation voltage variably adjustable | μA-connector for double platinum electrodes, connection: 2 x 4 mm – sockets), polarisation voltage variably adjustable | μA-connector for double platinum electrodes, connection: 2 x 4 mm – sockets), polarisation voltage variably adjustable |
Interchangeable burettes | 5, 10, 20 ml or 50 ml intelligent interchangeable burette units | 5, 10, 20 ml or 50 ml intelligent interchangeable burette units | 5, 10, 20 ml or 50 ml intelligent interchangeable burette units |
Dosing accuracy | according to DIN ISO 8655, part 3: accuracy: < 0.15 % precision: < 0.05 – 0.07 % (in dependence of the used burette size) | according to DIN ISO 8655, part 3: accuracy: < 0.15 % precision: < 0.05 – 0.07 % (in dependence of the used burette size) | according to DIN ISO 8655, part 3: accuracy: < 0.15 % precision: < 0.05 – 0.07 % (in dependence of the used burette size) |
Ambient conditions | Ambient temperature: + 10 … + 40 °C for operation and storage Humidity according to EN 61 010, Part 1: max. relative humidity 80 % for temperatures up to 31 °C, linear decrease down to 50 % relative humidity at a temperature of 40 °C | Ambient temperature: + 10 … + 40 °C for operation and storage Humidity according to EN 61 010, Part 1: max. relative humidity 80 % for temperatures up to 31 °C, linear decrease down to 50 % relative humidity at a temperature of 40 °C | Ambient temperature: + 10 … + 40 °C for operation and storage Humidity according to EN 61 010, Part 1: max. relative humidity 80 % for temperatures up to 31 °C, linear decrease down to 50 % relative humidity at a temperature of 40 °C |
Power supply | 100-240 V; 50/60 Hz, power input: 30 VA | 100-240 V; 50/60 Hz, power input: 30 VA | 100-240 V; 50/60 Hz, power input: 30 VA |
Stirring speed | 50 … 1000 U/min | 50 … 1000 U/min | 50 … 1000 U/min |
Dimensions (W x H x D (height without stand rod) | 80 x 130 x 250 mm | 80 x 130 x 250 mm | 80 x 130 x 250 mm |
Key Features
Titrator TitroLine® 7500 KF module with 20 ml exchangeable head
- Polarizable electrode input for set endpoint titrations („Dead-stop“ + KF)
- With standard methods for various applications such as titer determination, sample titration with 1- or 2-component reagent, etc.
- Volumetric KF titrations
- Also suitable for dosing tasks and sample preparation
- Formula editor for individual calculations
- User management/password
Key Industries
- Agriculture
- Environmental
- Food & Beverage
- Oil & Gas
- Pharmaceutical
More Products