Novasina-Humidity & Temperature Measurement

  • AUSTRALIA

    DKSH Australia Pty Ltd
    1 Beyer Road
    3195 Braeside VIC
    Australia

    1800 010 114 (hotline)

    Email

  • INDONESIA

    PT DKSH Indonesia
    12930 Jakarta Selatan
    Indonesia

    +62 21 2988 8557

    Email

  • JAPAN

    DKSH Japan K.K.
    3-4-19 Mita, Minato-ku
    108-8360 Tokyo
    Japan

    Email

  • CAMBODIA

    DKSH (Cambodia) Ltd
    Corner Preah Monivong Boulevard and Street 484
    Phnom Penh
    Cambodia

    +855 87 887 883

    Email

  • KOREA

    DKSH Korea Ltd.
    3rd Floor, Zen Building, 152 Dogok-ro, Gangnam-gu
    06261 Seoul
    Korea

    +82 2 2192 9723

    Email

  • LAOS

    DKSH Laos Company Ltd.
    3rd Floor, Vientiane Center Office Building Khouvieng Road, Sisattanak District
    Vientiane Capital
    Laos

    +856 21 221 023

    Email

  • MYANMAR

    DKSH (Myanmar) Ltd.
    Thitsar Road, Yankin Township
    Yangon
    Myanmar

    +951 8565270

    Email

  • NEW ZEALAND

    DKSH New Zealand Limited
    33 Westpoint Drive
    0618 Hobsonville, Auckland
    New Zealand

    0800 951 010

    Email

  • PHILIPPINES

    DKSH Philippines Inc.
    8th Floor Cyber Sigma, Lawton Ave., McKinley West, Fort Bonifacio
    1634 Taguig City
    Philippines

    +63 2 8548 3200

    Email

  • TAIWAN

    DKSH Taiwan Ltd.
    10th Floor, No.22, Lane 407, Section 2, Tiding Boulevard, Neihu District
    114-93 Taipei
    Taiwan

    +886 2 8752 7935

    Email

  • Novasina QuantDat / nSens factsheet


  • Novasina QuantDat/nSens spec sheet


  • Novasina ClimMate factsheet


  • Novasina ClimMate spec


  • Novasina HygroGuard / ClimaLog / DataLog factsheet


  • Novasina Hygromaxx / Statmaxx / Tempmaxx factshet


  • Novasina HygroMaxx spec sheet


  • Novasina StatMaxx spec sheet


  • Novasina TempMaxx spec sheet


  • Application Overview


  • Application note: Bakery


  • Application note: Powder & Spices


  • Application note: Meat


  • Application note: Pharma


  • Application note: Pet Food


  • Application note: Cannabis


  • Application note: Shelf Life Simplified


  • QuantDat/nSens: Multi-sensor industrial transmitter for humidity and temperature probes.
  • ClimMate: Mobile reference measuring instrument for humidity and temperature in a set.
  • HygroGuard/ClimaLog/DataLog: Data logger systems with internal and external sensors.
  • HygroMaxx: HVAC-transmitter for humidity and temperature measurement with analogue outputs.
  • StatMaxx: HVAC-thermo-hygrostat with integrated relay switches.
  • TempMaxx: HVAC-temperature transmitter with integrated relay switch and analogue output.

Available Models

Technical Specifications

Power supply24V +/- 15% AC or DC (galvanic isolated)
Power consumptionmax. ca.3W
DisplayGraphical display with LED backlight, 128 x 64 Pixel
Selectable parametersHumidity; Temperature; Mixing ratio; Water vapour partial pressure; Dew-point temperature; Specific enthalpy; Absolute humidity
Analogue outputs4 scalable & adjustable analogue outputs, 0/4..20mA or 0/2..10V
Digital outputsRS-485 Version with relay: 2 relay contacts, switching power <=50V/2A/60W
Housing materialABS – lid blue RAL 5014, bottom grey RAL 7035
Protection classIP54
Operating temperature0 to 50°C
Storage temperature-10 to + 60°C (non-condensing)
CE-/EMC compatibilitySafety: IEC 61010-1:2010 EMC: IEC 61000-6-2:2005, EN 61000-6-2:2005 IEC: 61000-6-3:2006+A1:2010, EN 61000-6-3:2007+A1:2011

Multi-sensor measurement system with intelligent and robust humidity/temperature sensors and analog signal exits.

This cost-efficient solution allows the user to connect up to four external digital nSens-HT humidity and temperature sensors with one transmitter.

Key Features

  • Reduced costs per measuring point thanks to multi-sensor architecture
  • High accuracy, reproducible measurement, no detectable hysteresis
  • Linear and fast response up to the humidity saturation level
  • Automatic probe identification
  • Graphics and illuminated display
  • Exchangeable sensor with stored calibration data

Technical Specifications

Operation / display unitClimMate – multifunction handheld measuring instrument
Power supply4 x 1.5VDC alkaline batteries or USB +5V power supply unit
Power consumptionapprox. 400 mW, battery lifetime approx.1 year, confi gurable Auto-Off
DisplayGraphic display TFT 240 x 320, capacitive touch display
Dimensions / WeightExternal dimensions: W62 x D34 x H170 mm (without probe)
Weight:approx. 200 gr
Measuring parametersrelative humidity; temperature (nSens-HT): accuracy see below abs.press. 800-1100mbar (integrated): accuracy @25°C +/-0.5mbar calculated parameters: mixing ratio; water vapor pressure; dew point temperature, abs. humidity; wet bulb temp.; water activity etc.
InterfacesUSB for connection to PC / UMB for connection of external probes
Protection classIP54
Operating temperature0 to 50°C
Storage temperature-20 to +80° C

Portable, battery-powered measuring and reference instrument for measurement of relative air humidity, temperature, absolute pressure, air velocity, air flow rate, C02 and water activity.

Key Features

  • Integrated data storage
  • Data visualizing software and SAL-SC humidity generator for calibration included in scope of delivery
  • Large, colour LCD-Touchscreen
  • Above average accuracy, reproducible measurement, no detectable hysteresis
  • Linear and fast response up to humidity saturation level
  • Intelligent, robust humidity/temperature sensor with stored calibration data

Technical Specifications

HygroGuard 30ClimaLog 30DataLog 30
Working range sensorrel. humidity 0…95% Temperature -20…50°Crel. humidity 0…95% Temperature -20…50°C Abs. pressure 0..10’000m 300…1’300 hPaexternal sensors UMB-bus & 2 AI I :0…20mA U:0..10V
Measurement principle%RH : capacitive Temp : NTC%RH : capacitive Temp : NTC hPa : piezosee connected sensors!
Accuracy%RH : +/- 2% Temp : +/-0.3°C%RH : +/- 2% Temp : +/-0.3°C hPa : +/-0.5 hPa at 25°Csee connected sensors!
Resolution%RH : 0.5% Temp : 0.1 °C%RH : 0.5% Temp : 0.1 °C hPa : 0.1 hPa
Dimension166x78x32 mm plastic housing166x78x32 mm plastic housing166x78x32 mm plastic housing
Weightapprox. 250 grapprox. 250 grapprox. 250 gr
LCD screespecifi c 3 line segment LCD with status, Alarm, data, time, connectionspecifi c 3 line segment LCD with status, Alarm, data, time, connectionspecifi c 3 line segment LCD with status, Alarm, data, time, connection
Power supply4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option)4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option)4xAA LR6 battery (>1 year life time) or/and +5V USB interface (PoE option)
InterfacesUSB, LAN (ethernet TCP/IP), UMB-busUSB, LAN (ethernet TCP/IP), UMB-busUSB, LAN (ethernet TCP/IP), UMB-bus
Memory16 MB – 3’200’000 data points16 MB – 3’200’000 data points16 MB – 3’200’000 data points
Meas. interval10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h10 / 30 s, 1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
Memory interval1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h1 / 10 / 12 / 15 / 30 min, 1 / 3 / 6 / 12 / 24 h
Operation cond-20…+50°C / 0….95%RH (no condensation) / 10’000m a.s.l.-20…+50°C / 0….95%RH (no condensation) / 10’000m a.s.l.-20…+50°C / 0….95%RH (no condensation) / 10’000m a.s.l.

Efficient Data loggers with built-in or external humidity, temperature or pressure sensor, which can be used both autonomous as a battery-powered unit or integrated into a network.

These analyzers are characterized by their diverse applicability, their high precision measurement and the recording of the desired climatic parameters. Therefore, an individual adaptation to the user’s needs is possible.

Key Features

  • Possibility for room mapping with external sensors
  • Large data storage of 3,2 million data points
  • Large display with additional acoustic alerting
  • User-friendly software for visualizing, analyzing and exporting of the data
  • Possibility to connect to a LAN-network  

Technical Specifications

HygroMaxx SHygroMaxx RHygroMaxx M
Dimensions183 x 110 x 50 mm118 x 110 x 300 mm118 x 110 x 50 mm
Measurement range humidity0 …. 100 % rH0 …. 100 % rH0 …. 100 % rH
Measurement range temperature-20 … +80°C / -4 … + 176 °F-20 … +80°C / -4 … + 176 °F-20 … +80°C / -4 … + 176 °F
Accuracy humidity standard+/- 3.0 % rH+/- 3.0 % rH+/- 3.0 % rH
Accuracy humidity with factory calibration+/- 1.5 % rH with 3 point calibration (11..53..90% rH)+/- 1.5 % rH with 3 point calibration (11..53..90% rH)+/- 1.5 % rH with 3 point calibration (11..53..90% rH)
Display resolution0.1 % rH 0.1°C / 0.1°F0.1 % rH 0.1°C / 0.1°F0.1 % rH 0.1°C / 0.1°F
Reproducibility humidity+/- 1.0 % rH range : 10 … 85% rH+/- 1.0 % rH range : 10 … 85% rH+/- 1.0 % rH range : 10 … 85% rH
Reproducibility temperature+/- 0.1 °C range : 0 … 60°C+/- 0.1 °C range : 0 … 60°C+/- 0.1 °C range : 0 … 60°C
Operating temperatureelectronics : 0… +50°C sensor : -20 … + 80°Celectronics : 0… +50°C sensor : -20 … + 80°Celectronics : 0… +50°C sensor : -20 … + 80°C
Long term stability of rH measurement< +/- 0.5 % rH / year at max. chemical working concentration< +/- 0.5 % rH / year at max. chemical working concentration< +/- 0.5 % rH / year at max. chemical working concentration
Power supply24 VDC +/- 25% In-Out without galvanic isolation24 VDC +/- 25% In-Out without galvanic isolation24 VDC +/- 25% In-Out without galvanic isolation
Norm tests / storage conditions Electromagnetic compatibilityEN 61326-1 / EN 61326 / A1EN 61326-1 / EN 61326 / A1EN 61326-1 / EN 61326 / A1
IP-protection / protection normIP 54 / EN 61010-1IP 54 / EN 61010-1IP 54 / EN 61010-1
Storage temperature (device)5 …. 60 °C ( not condensing )5 …. 60 °C ( not condensing )5 …. 60 °C ( not condensing )
Storage air humidity (device)5 …. 80% rH ( not condensing )5 …. 80% rH ( not condensing )5 …. 80% rH ( not condensing )

The ideal Thermo-Hygrometer for measurements of relative air humidity and temperature in room or duct applications in the HVAC industry.

A digital, capacitive humidity measuring element, combined with modern electronic-architecture, allows a multifunctional usage with high measurement precision and simple application.

Key Features

  • Different mounting forms for wall and duct installation
  • Large, well laid-out display
  • Simple to configure and calibrate
  • Scalable, analogue signal: mA or V
  • User-friendly menu structure with password protection

Technical Specifications

StatMaxx SStatMaxx RStatMaxx M
Dimensions183 x 110 x 50 mm118 x 110 x 300 mm118 x 110 x 50 mm
Measurement range humidity0 …. 100 % rH0 …. 100 % rH0 …. 100 % rH
Measurement range temperature-20 … +80°C-20 … +80°C-20 … +80°C
Accuracy humidity-standard+/- 3.0 % rH+/- 3.0 % rH+/- 3.0 % rH
Accuracy humidity with factory calibration+/- 1.5 % rH with 3 point calibration (11..53..90% rH)+/- 1.5 % rH with 3 point calibration (11..53..90% rH)+/- 1.5 % rH with 3 point calibration (11..53..90% rH)
Display resolution0.1 % rH 0.1°C / 0.1°F0.1 % rH 0.1°C / 0.1°F0.1 % rH 0.1°C / 0.1°F
Reproducibility humidity+/- 1.0 % rH range : 10 … 85% rH+/- 1.0 % rH range : 10 … 85% rH+/- 1.0 % rH range : 10 … 85% rH
Reproducibility temperature+/- 0.1 °C range : 0 … 60°C+/- 0.1 °C range : 0 … 60°C+/- 0.1 °C range : 0 … 60°C
Operating temperatureelectronics : 0… +50°C sensor : -20 … + 80°Celectronics : 0… +50°C sensor : -20 … + 80°Celectronics : 0… +50°C sensor : -20 … + 80°C
Long term stability of rH measurement< +/- 0.5 % rH / year at max. chemical working concentration< +/- 0.5 % rH / year at max. chemical working concentration< +/- 0.5 % rH / year at max. chemical working concentration
Power supply24 VDC +/- 20%24 VDC +/- 20%24 VDC +/- 20%
Norm tests / storage conditions Electromagnetic compatibilityEN 61326-1 / EN 61326 A1EN 61326-1 / EN 61326 A1EN 61326-1 / EN 61326 A1
IP-protection / protection normIP 54 / EN 61010-1IP 54 / EN 61010-1IP 54 / EN 61010-1
Storage temperature (device)5 …. 60 °C ( not condensing )5 …. 60 °C ( not condensing )5 …. 60 °C ( not condensing )
Storage air humidity (device)5 …. 80% rH ( not condensing )5 …. 80% rH ( not condensing )5 …. 80% rH ( not condensing )

This Thermo-Hygrostat with integrated relay switch is particularly useful for monitoring, supervision and regulation tasks in HVAC applications.

Different mounting forms for wall and duct installations allow a customized use of the StatMaxx.

Key Features

  • Large and well laid-out display
  • Simple to configure and calibrate
  • Integrated switching contact with configurable switching threshold function
  • User-friendly menu structure with password protection

Technical Specifications

Dimensions183 x 110 x 50 mm
Measurement range temp. measurement PT/Ni 100-50…+400°C 2-, 3- or 4-wire connection
Measurement range temp. measurement PT 1’000-50…+400°C 2-, 3- or 4-wire connection
Measurement range temp. measurement Ni 1’000-50…+200°C 2-, 3- or 4-wire connection
Measurement range temp. measurement Beta Therm-20…+80°C +/- 0,2 K 2-wire connection
Display resolution0.1°C / 0.1°F
Sensor break detectionYES (display): at 2…10V and 4..20 mA = per 0 VAC / 0 mA
Repeatability temperaturedepending on probe according to DIN EN 60751 AA, A, B, 1/3B, C
Operating temperatureelectronics : -10…+50°C sensor : -50…+400°C
Long term stability of rH measurement< +/- 0.5 % rH / year at max. chemical working concentration
Power supply18…35 (24 VDC +/- 25%) without galvanic isolation 50…100mA depending on initial condition
Accuracy+/- 0.15% FS accuracy without sensor element over full measurement range
Password protectionYES 4-digit code for all settings
Special funtions: Alarm functionHigh, Low, Hysteresis, Delay, NC or NO (On/OFF)
2-point control fuctionSetpoint, Hysteresis, Delay, NC or NO (On/OFF)
Norm tests/storage conditions: Electromagnetic compatibilityIEC 61000-6-2 / IEC 61000-6-4 / EN 61000-6-2 / EN 61000-6-4
IP-protection / CE-NormIP 41 / EN 61010-1
Storage temperature (device)5 …. 60 °C ( not condensing )
Storage air humidity (device)5 …. 80% rH ( not condensing )

Universal temperature transmitter with analogue output and relay switch especially developed for demanding HVAC applications.

This analyzer is characterized by its possibility to connect with various temperature sensors. Further, it is simple to configure, to mount and to calibrate.

Key Features

  • Connection with standard PT100, PT1000 and NTC sensors
  • Large and well laid-out display
  • Integrated switching contact with configurable switching threshold function
  • Scalable, analogue signal: mA or V
  • User-friendly menu structure with password protection

Application Notes

Success Stories

Successfully Flowing Into New Market Segments

Though Novasina’s product has been widely accepted in the meat processing segment, in Japan it had not made much headway in other business segments. Novasina needed to identify opportunities in other industries to grow its business presence in Japan.

Read Full Story

Key Industries

  • Agriculture
  • Biopharmaceutical and Biotechnology
  • Cosmetics & Personal Care
  • Education & Academics
  • Electronics
  • Food & Beverage
  • Optical
  • Pharmaceutical
  • Semiconductor, Solar & Electronics
  • Service
  • Textile

Brand

Novasina

Since its establishment more than 50 years ago, the company Novasina has specialised in the accurate measuring of air and material humidity. Novasina fully develops and produces precision measuring devices and includes always its long lasting know-how. We are proud of the “SWISS MADE” label, which guarantees our customers highest quality, innovation and longevity.

Similar Products

test block for Laos

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Your download – just a few steps away

Please enter your details here:

test

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us