The improved performance and reliability of the new platform have added more analytical capability and power for X-ray scattering studies in:

  • advanced materials science
  • scientific and industrial thin film technology
  • metrological characterization in semiconductor process development

Technical Specifications

Goniometer- Step SizeMinimum step size 0.0001˚
Goniometer- RadiusRadius: X’Pert³ MRD 320 mm (horizontal); Radius: X’Pert³ MRD XL 420 mm (horizontal)
Open Eulerian Cradle- Chi Rotation+/- 92˚
Open Eulerian Cradle- Phi Rotation2 x 360˚
Open Eulerian Cradle- x,y translation100 x 100 mm (X’Pert³ MRD); 200 x 200 mm (X’Pert³ MRD XL)
Open Eulerian Cradle- z translationminimum step size 1 µm
C-to-C Wafer Loaders- Size2” to 150 mm; 100 to 300 mm

Available Models

Technical Specifications

Goniometer- Step SizeMinimum step size 0.0001˚
Goniometer- RadiusRadius: X’Pert³ MRD 320 mm (horizontal); Radius: X’Pert³ MRD XL 420 mm (horizontal)
Open Eulerian Cradle- Chi Rotation+/- 92˚
Open Eulerian Cradle- Phi Rotation2 x 360˚
Open Eulerian Cradle- x,y translation100 x 100 mm (X’Pert³ MRD); 200 x 200 mm (X’Pert³ MRD XL)
Open Eulerian Cradle- z translationminimum step size 1 µm
C-to-C Wafer Loaders- Size2” to 150 mm; 100 to 300 mm

The standard research and development version for use with thin film samples, wafers (complete mapping up to 100 mm) and solid materials. High-resolution analysis capability is improved by the outstanding accuracy of a new high-resolution goniometer using Heidenhain encoders. 

Technical Specifications

Goniometer- Step SizeMinimum step size 0.0001˚
Goniometer- RadiusRadius: X’Pert³ MRD 320 mm (horizontal); Radius: X’Pert³ MRD XL 420 mm (horizontal)
Open Eulerian Cradle- Chi Rotation+/- 92˚
Open Eulerian Cradle- Phi Rotation2 x 360˚
Open Eulerian Cradle- x,y translation100 x 100 mm (X’Pert³ MRD); 200 x 200 mm (X’Pert³ MRD XL)
Open Eulerian Cradle- z translationminimum step size 1 µm
C-to-C Wafer Loaders- Size2” to 150 mm; 100 to 300 mm

The X’Pert³ MRD XL meets all the high-resolution XRD analysis requirements of the semiconductors, thin films, and advanced materials industries. Complete wafer mapping up to 200 mm is possible. The X’Pert3 version comes with longest liftetime of incident beam components (CRISP) and maximum uptime with pneumatic shutters and beam attenuators. By facilitating analysis of wafers of up to 300 mm in diameter, with a sophisticated, automatic wafer loader option, the X’Pert³ MRD XL becomes an advanced tool for quality control of industrial thin layered structures. 

Technical Specifications

Enclosure- Dimensions1400 (w) x 1162 (d) x 1947 (h) mm
Enclosure- Weight1150 kg
Enclosure- AccessibilityLarge doors, allowing access for up to four people simultaneously
Enclosure- SafetyMeets all relevant worldwide regulations for electrical, mechanical and X-ray safety, with all anode types
Enclosure- Set-upSystem is on wheels for easy installation and relocation
Goniometer- ConfigurationVertical goniometer, available in theta-theta or alpha-1 geometry
Goniometer- Radius and Interface240 mm radius, interfaces are available to reduce the diffracted beam radius for specific applications
Goniometer- Usable RangeMaximum usable range (depending on accessories) -111°< 2θ <168°
Goniometer- Linearity2θ linearity equal or better than ±0.01°
Goniometer- Accuracy and PrecisionNew generation direct optical encoding system (DOPS 2) for lifetime goniometer accuracy, using precisely aligned Heidenhain encoders and path tracking technology
X-Ray Source- X-Ray TubeFully ceramic X-ray tubes manufactured by PANalytical’s specialized factory under cleanroom conditions
X-Ray Source- Generator4 kW generator supporting all current and future X-ray tubes
X-Ray Source- PerformanceAll Empyrean instruments are designed for 60 kV operation, allowing optimal performance for Mo and Ag sources

The X’Pert³ Extended MRD (XL) brings increased versatility to the range of X’Pert³ MRD systems. An extra PreFIX mounting platform allows mounting of an X-ray mirror and a high-resolution monochromator in-line, increasing significantly the intensity of the incident beam. One can benefit from increased application versatility without compromise on data quality, high-resolution X-ray diffraction with high intensities, shorter measurement times for measurements such as reciprocal space mapping and rebuild from standard to extended configuration in minutes thanks to the PreFIX concept. With the 2nd generation PreFIX, reconfiguring is easy and optics positioning is more accurate than ever. 

Technical Specifications

Enclosure- DimI3:J22ensions1400 (w) x 1162 (d) x 1947 (h) mm
Enclosure- Weight1150 kg
Enclosure- AccessibilityLarge doors, allowing access for up to four people simultaneously
Enclosure- SafetyMeets all relevant worldwide regulations for electrical, mechanical and X-ray safety, with all anode types
Enclosure- Set-upSystem is on wheels for easy installation and relocation
Goniometer- ConfigurationVertical goniometer, available in theta-theta or alpha-1 geometry
Goniometer- Radius and Interface240 mm radius, interfaces are available to reduce the diffracted beam radius for specific applications
Goniometer- Usable RangeMaximum usable range (depending on accessories) -111°< 2θ <168°
Goniometer- Linearity2θ linearity equal or better than ±0.01°
Goniometer- Accuracy and PrecisionNew generation direct optical encoding system (DOPS 2) for lifetime goniometer accuracy, using precisely aligned Heidenhain encoders and path tracking technology
X-Ray Source- X-Ray TubeFully ceramic X-ray tubes manufactured by PANalytical’s specialized factory under cleanroom conditions
X-Ray Source- Generator4 kW generator supporting all current and future X-ray tubes
X-Ray Source- PerformanceAll Empyrean instruments are designed for 60 kV operation, allowing optimal performance for Mo and Ag sources

With the X’Pert³ MRD (XL) system for in-plane diffraction, it becomes possible to measure diffraction from lattice planes that are perpendicular to the sample surface.

Standard and in-plane geometries on one system and a wide range of diffraction experiments on polycrystalline and highly perfect thin films, are just two of many benefits.  

Key Features

  • Wafer mapping up to 200 mm meets all the high-resolution XRD analysis requirements.
  • High-resolution analysis capability is improved by the outstanding accuracy of a new high-resolution goniometer using Heidenhain encoders.
  • Provides the longest liftetime of incident beam components (CRISP) and maximum uptime with pneumatic shutters and beam attenuators.
  • With the 2nd generation PreFIX mounting platform, reconfiguring is easy within minutes and optics positioning is more accurate than ever.
  • Allows for the measurement of diffraction from lattice planes that are perpendicular to the sample surface.
  • Possible standard and in-plane geometries on one system and a wide range of diffraction experiments on polycrystalline and highly perfect thin films.

Key Industries

  • Die & Mould
  • Electronics
  • Powders & Pigments / Coating
  • Semiconductor, Solar & Electronics
Malvern Panalytical

Malvern Panalytical was formed by the merger of Malvern Instruments Limited and Panalytical B.V. on 1st January 2017, has headquarters…





  • CAMBODIA

    DKSH (Cambodia) Ltd Corner Preah Monivong Boulevard and Street 484 Phnom Penh Cambodia

    +855 87 887 883

    Contact Now

  • LAOS

    DKSH Laos Company Ltd. 3rd Floor, Vientiane Center Office Building Khouvieng Road, Sisattanak District Vientiane Capital Laos

    +856 21 221 023

    Contact Now

  • MALAYSIA

    DKSH Technology Sdn. Bhd. B-11-01, The Ascent, Paradigm, No. 1, Jalan SS7/26A, Kelana Jaya 47301 Petaling Jaya, Selangor Malaysia

    +60 3 7882 8711

    Contact Now

  • MYANMAR

    DKSH (Myanmar) Ltd. Thitsar Road, Yankin Township Yangon Myanmar

    +951 8565270

    Contact Now

  • PHILIPPINES

    DKSH Philippines Inc. 8th Floor Cyber Sigma, Lawton Ave., McKinley West, Fort Bonifacio 1634 Taguig City Philippines

    +63 2 8548 3200

    Contact Now

  • THAILAND

    DKSH Technology Limited (Head Office) 2533 Sukhumvit Road, Bangchak, Phrakhanong 10260 Bangkok Thailand

    +66 2 639 7000

    Contact Now

  • VIETNAM

    DKSH Technology 1st, 2nd Floor, Etown 2, 364 Cong Hoa Str., Tan Binh Dist. 70000 Ho Chi Minh City Vietnam

    +84 28 3812 5848

    Contact Now

Business Lines

Commercial and Industrial Applications

Precision Machinery

Scientific Solutions

Semiconductor & Electronics

Order Online

LabShop

Delivering Growth – in Asia and Beyond

test block for Laos

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Your download – just a few steps away

Please enter your details here:

test

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us