HF Scientific – Environmental Testing Equipment – AdvantEDGE Optical Dissolved Oxygen RDO® Electrode
Measures dissolved oxygen (DO) in demanding environments
The AdvantEDGE Optical Dissolved Oxygen RDO® Electrode uses the latest technology to measure dissolved oxygen (DO) in demanding environments. The AdvantEDGE Series™ Optical Dissolved Oxygen RDO® sensor offers several advantages for monitoring DO in process applications.
Technical Specifications
Sensor Type | Luminescent dissolved oxygen sensor |
Transmitter/local display | Optional, not required |
---|---|
Range | 0 to 20 mg/L concentration0 to 200% saturation |
Accuracy (DO) | ±0.1 mg/L, 0 to 8 mg/L±0.2 mg/L, 8 to 20 mg/L |
Response time, cap | T90: 30 sec T95: 37 sec @ 25°C |
Resolution | 0.01 mg/L |
Usage life of cap | 1 year from the first instrument reading |
Shelf life of cap | 2 years from date of manufacture(install within 1 year from date of manufacture) |
Operating temperature | 0° to 50° (32° to 122°F) |
IP rating | IP-67 with cap off, IP-68 with cap installed |
Compliance | Heavy industrial, IEC 61000-6-2:2005 |
Storage conditions, cap | 1° to 60° (33° to 140°F), in factory container |
Storage conditions, sensor | -5° to 60° (23° to 140°F) |
Salinity range | 0 to 42 PSU, fixed or real-time capable |
pH range | 2-10 pH |
Barometric range | 507-1115 mbar, fixed or real-time capable |
Internal mounting thread | 1¼-11½ NPT |
Communications options | Modbus RTU (RS485), 4-20mA, SDI-12 |
Maximum cable length | Up to 4000 ft (Modbus and 4-20 mA)or up to 200 ft (SDI-12) |
Warranty | Sensor: 3 years from date of manufactureCap: 2 years from date of manufacture |
Key Features
- Robust: Inert construction will not corrode in high salinity samples; Insensitive to common interferences such as hydrogen sulfide, chloride, chlorine, ammonium, and many others
- Cost effective options: Choose models for use with the economical LD500 Local Display; providing 4-20mA outputs and various communications protocols; Choose models available with integral 4-20 mA, Modbus RS-485, and SDI-12 outputs for direct connection to SCADA or PLC; totally eliminating the need for a separate transmitter/controller
- No calibration hassles: When used with the LD500 Local Display, no calibration is required; When connected directly to a SCADA or PLC, a one-time calibration is performed that lasts for 12 months
- Low maintenance: No electrolyte or membranes to replace; Sensor cap lasts 1 year without the need for recalibrations; Simply wipe the sensor cap periodically. Optional air blast accessory available
- Accurate: 0.1 mg/L accuracy from 0 – 8 mg/L DO, and 0.2 mg/L accuracy from 8 to 20 mg/L DO; Fast response to oxygen and temperature changes; Consistent, reproducible results (<0.05 mg/L reproducibility)
Key Industries
- Aerospace
- Agriculture
- Automotive
- Biopharmaceutical and Biotechnology
- Chemical
- Construction
- Cosmetics & Personal Care
- Defense
- Die & Mould
- Education & Academics
- Electronics
- Energy
- Environmental
- Food & Beverage
- Luxury
- Machinery & Manufacturing
- Medical
- Mining & Minerals
- Oil & Gas
- Optical
- Paper & Wood
- Pharmaceutical
- Polymers, Plastics and Rubbers
- Powders & Pigments / Coating
- Railway
- Semiconductor, Solar & Electronics
- Service
- Textile
- Wholesale & Retail
More Products
HF Scientific is a quality innovator of instrumentation focused on the measurement of cleanwater. They offer laboratory and on-line instruments…