Agilent J&W GC columns are available in a wide variety of stationary phases, offering a solution for your gas chromatography analysis.

Agilent J&W GC columns help lab analysts maintain the highest standards of performance. The columns deliver industry-leading technology with the highest inertness, lowest bleed levels, and tightest column-to-column reproducibility specifications. We offer specific GC columns for the Intuvo 9000 GC, columns for the 8890 GC that have a Smart Key included as well as Low Thermal Mass columns and packed GC columns for applications such as hydrocarbon processing. If a column is required that isn’t part of our standard offering, a custom GC column can be built to order.

Key Features

With the highest inertness, lowest bleed levels, and the tightest column-to-column reproducibility, Agilent J&W GC Capillary columns perform better than any columns on the market.

GC Capillary Columns

  • Ultra inert Columns â€“ allow you to perform trace level analysis – including the analysis of acids, bases, or other active compounds – with the utmost confidence. They also help ensure an inert GC flow path that is essential for sensitivity, performance, and the integrity of your analytical results.
  • Llow-bleed GC/MS Columns â€“ are specifically designed to chromatograph a broad range of trace-level samples, and offer low bleed and high inertness even at higher temperatures.
  • Premium Polysiloxane Columns â€“ are stable, robust, and versatile and are available in a wide variety of stationary phases.
  • Polyethylene Glycol (PeG) Columns â€“ offer a variety of unique phase characteristics to meet the varying needs of your laboratory, thanks to Agilent’s strict quality control of the cross-linking and deactivation processes.
  • Specialty Columns â€“ meet Agilent’s uncompromising standards for high-temperature, life science, pesticide, petroleum, semivolatile, and volatile applications.
  • Plot Columns â€“ deliver superior separation for compounds that are gases at room temperature. They are also ideal for analyzing fixed gases, low molecular weight hydrocarbon isomers, volatile polymer compounds, and reactive analytes such as gases, amines, and hydrides.

All Categories

  • Ultra Inert GC Columns
  • Intuvo GC Columns
  • High Temperature GC Columns
  • LTM GC Columns
  • Low Bleed GC/MS Columns
  • PLOT GC Columns
  • Chiral GC Columns
  • Packed Columns
  • Standard Polysiloxane GC Columns
  • Application Specific GC Columns
  • GC Columns with Smart Key
  • WAX GC Columns
  • Metal GC Columns
  • Guard Columns and Capillary Tubing

Low-Bleed GC/Ms columns

There is a rapidly increasing population of benchtop GC/MS instruments in analytical laboratories that analyze a widening range of trace level, higher temperature samples. These samples require increasingly inert, lower bleed, higher temperature columns. In response to this growing need, Agilent Technologies designed several “ms” columns to chromatograph a broader range of low level samples and generate lower bleed even at higher temperatures.

What makes an Agilent J&W low-bleed column exceptional? Unique polymer chemistry and proprietary surface deactivation, both of which have contributed to columns that adhere to the tightest quality control specifications in the industry for bleed, inertness, selectivity and efficiency. Agilent J&W “ms” columns utilize special surface deactivation and siloxane chemistries which enhance the chromatographic performance of siloxane polymers.

The mass spectrum of septum bleed can look very much like GC column bleed, so the two are often confused. An easy way to tell the two apart: column bleed will be indicated by a rise in the baseline, not peaks. If you see bleed peaks, these generally come from lower quality septa or septa being used beyond their operating limits. To minimize septa contributions to background bleed, use quality Agilent BTO, Long-Life, or Advanced Green septa.

DB-1ms

  • 100% Dimethylpolysiloxane
  • Identical selectivity to DB-1
  • Non-polar
  • Very low bleed characteristics, ideal for GC/MS
  • Improved acid performance compared to standard 100% dimethylpolysiloxane columns
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • 340/360 °C upper temperature limit
  • Excellent general purpose column
  • Bonded and cross-linked
  • Solvent rinsable

Similar Phases: SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1, MDN-1, ZB-1, ZB-1ms

HP-1Ms

  • 100% Dimethylpolysiloxane
  • Identical selectivity to HP-1
  • Non-polar
  • Low bleed characteristics
  • Excellent general purpose column
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • Bonded and cross-linked
  • Solvent rinsable

Similar Phases: Rtx-1ms, Rxi-1ms, MDN-1, AT-1, ZB-1ms, Equity-1

VF-1ms

  • Highly inert, non-polar 100% dimethylpolysiloxane phase, low-bleed GC column providing increased sensitivity over a broad array of applications
  • Ultra low bleed specification of 1 pA at 325 °C (30 m, 0.25 mm, 0.25 μm) for trace analysis with MS
  • QC test results for retention index, efficiency, selectivity and bleed is reported with every column
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: Rtx-1ms, Rxi-1ms, MDN-1, AT-1, ZB-1ms, Equity-1

DB-5ms

  • Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane
  • Non-polar
  • Very low bleed characteristics, ideal for GC/MS
  • Excellent inertness for active compounds
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • Bonded and cross-linked
  • Solvent rinsable
  • Exact replacement of HP-5TA
  • Close equivalent to USP Phase G27
  • Test mix available

similar Phases: Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, PTE-5, BPX-5, AT-5ms, ZB-5ms, ZB-5MSi, SLB-5ms, Equity-5

HP-5ms

  • (5%-Phenyl)-methylpolysiloxane
  • Identical selectivity to HP-5
  • Non-polar
  • Very low bleed characteristics, ideal for GC/MS
  • Excellent inertness for active compounds including acidic and basic compounds
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • Bonded and cross-linked
  • Solvent rinsable
  • Equivalent to USP Phase G27

Similar Phases: Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, PTE-5, BPX-5, AT-5ms, ZB-5ms, SLB-5ms, Equity-5

VF-5ms

  • Highly inert 5% phenylmethyl column for increased sensitivity, accuracy and instrument uptime
  • Minimal column bleed improves sensitivity – ultra low bleed specification of 1 pA at 325 °C (30 m x 0.25 mm, 0.25 μm)
  • Slightly higher polarity than VF-1ms, results in improved selectivity for aromatic compounds; selectivity and excellent inertness make these columns applicable for a wide range of semi-polar and even polar compounds
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • QC test results for retention index, efficiency, selectivity and bleed is reported with every column
  • Supplied with EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: Rtx-5ms, Rxi-5ms, Rxi-5Sil MS, PTE-5, BPX-5, AT-5ms, ZB-5ms, ZB-5MSi, SLB-5ms, Equity-5

DB-XlB

  • Exceptionally low bleed
  • Low polarity
  • Extended temperature limit of 340/360 °C
  • Unique selectivity
  • Excellent inertness for active compounds
  • Ideal for confirmational analyses
  • Excellent for pesticides, herbicides, PCBs and PAHs
  • Ideal for GC/MS
  • Bonded and cross-linked
  • Solvent rinsable

note: DB-XLB is designed for inhibiting column bleed at high temperatures. It also appears to have inadvertently inherited an exceptional ability for separating many PCB congeners when used with MS detection. This stellar performance was maximized after careful optimization of the column dimensions, temperature programs, and carrier gas flow conditions.

(Frame, G. Analytical Chemistry News & Features, Aug. 1, 1997, 468A-475A)

Similar Phases: Rtx-XLB, MDN-12, ZB-XLB, ZB-XLB HT

VF-Xms

  • High arylene modified phase for accurate results
  • Isothermal applications up to 340 °C for a broad application range
  • Ideal for confirmational analyses – more polar alternative to 5% phenyl columns
  • Ultra low bleed delivers ultimate sensitivity and signal-to-noise ratio
  • Provides exceptionally high selectivity for semivolatile compounds such as pesticides and delivers high resolution with short analysis time
  • Very unique selectivity for chlorinated compounds
  • QC test results for retention index, efficiency, selectivity and bleed is reported with every column
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: Rtx-XLB, MDN-12, ZB-XLB, ZB-XLB HT

DB-35ms

  • Virtually equivalent to a (35%-phenyl)-methylpolysiloxane
  • Mid-polarity
  • Very low bleed characteristics, ideal for GC/MS
  • Extended temperature limit of 340/360 °C
  • Excellent inertness for active compounds
  • Ideal for confirmational analyses
  • Bonded and cross-linked
  • Solvent rinsable
  • Replaces HP-35ms
  • Close equivalent to USP Phase G42

Similar Phases: Rtx-35, Rtx-35ms, Rxi-35Sil MS, SPB-35, AT-35, Sup-Herb, MDN-35, BPX-34, ZB-35, ZB-35 ht

VF-35ms

  • Stabilized arylene-modified equivalent of a 35% phenylmethyl phase
  • Ideal for dual column confirmational analyses
  • Ultra low bleed, highly stable column with a programmable maximum temperature of 360 °C
  • Medium polarity column ideal for trace environmental and chemical analyses
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: Rtx-35, Rtx-35ms, Rxi-35Sil MS, SPB-35, AT-35, Sup-Herb, MDN-35, BPX-34, ZB-35, ZB-35 ht

DB-17ms

  • Virtually equivalent to (50%-phenyl)-methylpolysiloxane
  • 320/340 °C upper temperature limit
  • Very low bleed mid-polarity column, ideal for GC/MS
  • Excellent inertness for active compounds
  • Enhanced mass spectral integrity
  • Bonded and cross-linked
  • Solvent rinsable
  • Excellent choice for CLP pesticides

Similar Phases: Rxi-17Sil MS, Rtx-50, 007-17, SP-2250, SPB-50, BPX-50, SPB-17, AT-50

VF-17ms

  • 50% phenyl/50% dimethylpolysiloxane, medium polarity phase
  • Ultra low bleed
  • Proprietary deactivation technology and manufacturing process improves column stability, resulting in improved column-to-column repeatability and column lifetimes
  • Ideal for environmental and clinical methods
  • Ultra low bleed specification at 2 pA at 325 °C (0.25 mm x 30 m, 0.25 μm)
  • Ideal EPA confirmation column for ultimate confidence
  • Bonded and cross-linked
  • Solvent rinsable
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: Rxi-17Sil MS, Rtx-50, 007-17, SP-2250, SPB-50, BPX-50, SPB-17, AT-50

VF-23ms

  • High polarity and highly substituted cyanopropyl low bleed phase
  • Engineered for accurate analysis of very polar analytes
  • 100% bonded phase permits column rinsing to enhance column lifetime
  • Operating temperature up to 260 °C
  • Expands application ranges to higher molecular weight compounds
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, BPX-70, SP-2340

VF-200ms

  • Trifluoropropyl phase has very high temperature stability and can be used routinely up to 350 °C
  • Ideally suited for analyses of ketones, aldehydes, nitro- or chloro-containing compounds, PAHs, unsaturated compounds, silanes, and CFCs
  • Optimized deactivation for symmetrical peak shape
  • Ultra-low bleed for trace analysis
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses

Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: Rtx-200

VF-WAXms

  • Specially designed WAX phase designed for accurate MS results with polar compounds
  • Operating temperature range of 20 °C to 250 °C
  • Improves signal-to-noise ratio for trace analyses
  • Ideal for GC/MS food, flavor and fragrance applications, especially where trace analyses are required
  • Ultra low bleed provides increased sensitivity and extended column lifetime at higher temperatures
  • Improved performance with no change in the typical selectivity of PEG
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: SUPELCOWAX 10, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, Rtx-WAX, ZB-WAX, ZB-WAX plus

VF-624ms and VF-1301ms

  • VF-624ms is designed for analyzing solvents according to EPA Methods 524, 624 and 8260, as well as USP 467
  • VF-1301ms ultra-low-bleed thin-film has a similar selectivity to 624 and is suitable for semivolatile organic solvents, as well as PCBs and pesticides
  • Enhanced selectivity for USP 467 eliminates co-elution of benzene and 1,2-dichloroethane
  • Mid polarity
  • Low bleed
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: AT-624, Rxi-624 Sil MS, Rtx-624, PE-624, 007-624, 007-502, ZB-624

VF-1701ms

  • Ultra-low bleed 14% cyanopropyl/phenyl/86% polydimethylsiloxane phase
  • Mid polarity
  • Ideal for pesticides, PCBs and semi-volatile organic compounds
  • Highly inert for difficult analytes such as p,p’-DDT
  • Deactivated for accurate trace analysis
  • Engineered for reduced bleed, (bleed specification is 2 pA at 280 °C for a 0.25 mm x 60 m, 0.25 μm id column)
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: SPB-1701, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-1701

Premium Polysolixane Columns

Polysiloxanes are the most common stationary phases. They are available in the greatest variety and are stable, robust and versatile. Standard polysiloxanes are characterized by the repeating siloxane backbone.

Each silicon atom contains two functional groups. The type and percent level of substitution of the groups distinguish each stationary phase and its properties.

DB-1

  • 100% Dimethylpolysiloxane
  • Non-polar
  • Excellent general purpose column
  • Wide range of applications
  • Low bleed
  • High temperature limit
  • Bonded and cross-linked
  • Solvent rinsable
  • Wide range of column dimensions available
  • Equivalent to USP Phase G2

Similar Phases: SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1, MDN-1, ZB-1

HP-1

  • 100% Dimethylpolysiloxane
  • Non-polar
  • Excellent general purpose column – “Industry Standard”
  • Wide range of applications
  • Superior performance for low molecular weight alcohols (<C5)
  • High temperature limit
  • Bonded and cross-linked
  • Solvent rinsable
  • Wide range of column dimensions available
  • Equivalent to USP Phase G2

Similar Phases: SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1, MDN-1, ZB-1

CP-Sil 5 CB

  • 100% Dimethylpolysiloxane
  • Non-polar
  • General purpose phase
  • Bonded and cross-linked
  • Solvent rinsable
  • Available in fused silica or UltiMetal
  • Separation almost entirely based on boiling points, making this column suitable
  • for a wide range of applications with a broad temperature range
  • High temperature limit
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1, MDN-1, ZB-1

Ultra 1

  • 100% Dimethylpolysiloxane
  • Non-polar
  • Equivalent to HP-1 with tighter specifications for retention index and capacity factors
  • Bonded and cross-linked
  • Solvent rinsable

Similar Phases: SPB-1, Rtx-1, BP-1, 007-1(MS)

Ultra 2

  • (5%-Phenyl)-methylpolysiloxane
  • Non-polar
  • Equivalent to HP-5 with tighter specifications for retention index and capacity factors
  • Bonded and cross-linked
  • Solvent rinsable
  • Similar Phases: SPB-5, Rtx-5, BP-5, CB-5, 007-5, 2B-5

DB-5

  • (5%-Phenyl)-methylpolysiloxane
  • Non-polar
  • Excellent general purpose column
  • Wide range of applications
  • Low bleed
  • High temperature limit
  • Bonded and cross-linked
  • Solvent rinsable
  • Wide range of column dimensions available
  • Equivalent to USP Phase G27

Similar Phases: SPB-5, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, PTE-5, ZB-5, AT-5, MDN-5, ZB-5

HP-5

  • (5%-Phenyl)-methylpolysiloxane
  • Non-polar
  • Excellent general purpose column
  • Wide range of applications
  • High temperature limit
  • Bonded and cross-linked
  • Solvent rinsable
  • Wide range of column dimensions available
  • Equivalent to USP Phase G27

Similar Phases: SPB-5, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, PTE-5, ZB-5, AT-5, MDN-5, ZB-5

CP-Sil 8 CB

  • (5%-Phenyl)-methylpolysiloxane
  • Non-polar
  • General purpose phase
  • Bonded and cross-linked
  • Solvent rinsable
  • Low bleed
  • High column-to-column reproducibility
  • Wide choice of dimensions available
  • Available in fused silica and UltiMetal
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: SPB-5, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, PTE-5, ZB-5, AT-5, MDN-5, ZB-5

CP-Sil 13 CB

  • 14% Phenyl/86% dimethylpolysiloxane
  • Mid polarity phase
  • Specially developed for the analysis of medium polarity compounds
  • Ideal for confirmational analyses using ECD
  • Bonded and cross-linked
  • Solvent rinsable
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: Rtx-20

DB-35

  • (35%-Phenyl)-methylpolysiloxane
  • Mid polarity – slightly more polar than HP-35
  • Low bleed
  • Inert to active solutes
  • Ideal for confirmational analyses
  • Bonded and cross-linked
  • Solvent rinsable
  • Equivalent to USP Phase G42

Similar Phases: Rtx-35, Rtx-35ms, Rxi-35Sil MS, SPB-35, AT-35, Sup-Herb, MDN-35, BPX-34, ZB-35, ZB-35 ht

HP-35

  • (35%-Phenyl)-methylpolysiloxane
  • Mid polarity – slightly less polar than DB-35
  • Inert to active solutes
  • Ideal for confirmational analyses
  • Bonded and cross-linked
  • Solvent rinsable
  • Equivalent to USP Phase G42

Similar Phases: Rtx-35ms, Rxi-35Sil MS, SPB-35, AT-35, Sup-Herb, MDN-35, BPX-34, ZB-35, ZB-35 ht

DB-17

  • (50%-Phenyl)-methylpolysiloxane
  • Mid polarity – slightly more polar than HP-50+
  • Excellent for confirmational analyses
  • Bonded and cross-linked
  • Solvent rinsable
  • Equivalent to USP Phase G3

Similar Phases: Rtx-50, 007-17(MPS-50), SP-2250, SPB-50, ZB-50, AT-50

HP-50+

  • (50%-Phenyl)-methylpolysiloxane
  • Mid polarity – slightly less polar than DB-17
  • Excellent for confirmational analyses
  • Bonded and cross-linked
  • Solvent rinsable
  • Equivalent to USP Phase G3

Similar Phases: Rtx-50, 007-17(MPS-50), SP-2250, SPB-50, ZB-50, AT-50

CP-sil 24 CB

  • 50% Phenyl/50% dimethylpolysiloxane
  • Mid polarity phase
  • Specially suitable for analysis of amines, drugs and pesticides
  • Ideal for analysis using ECD
  • Excellent confirmation column in combination with CP-Sil 5 CB or CP-Sil 8 CB
  • Bonded and cross-linked
  • Solvent rinsable
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: Rtx-50, 007-17(MPS-50), SP-2250, SPB-50, ZB-50, AT-50

DB-23

  • (50%-Cyanopropyl)-methylpolysiloxane
  • High polarity
  • Designed for separation of fatty acid methyl esters (FAMEs)
  • Excellent resolution for cis- and trans-isomers
  • Bonded and cross-linked
  • Solvent rinsable
  • Replaces HP-23
  • Close equivalent to USP Phase G5

Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, BPX-70, SP-2340

DB-200

  • (35% Trifluoropropyl)-methylpolysiloxane
  • 300/320 °C temperature limit
  • Mid polarity – more polar than DB-1701 or DB-17
  • Ideal for difficult-to-separate positional isomers
  • Unique interactions with compounds containing nitro, halogen and carbonyl groups
  • Low ECD bleed
  • Unique selectivity
  • Close equivalent to USP Phase G6

Similar Phases: Rtx-200

DB-210

  • (50%-Trifluoropropyl)-methylpolysiloxane
  • High polarity
  • Excellent for US EPA Methods 8140 and 609
  • Bonded and cross-linked
  • Solvent rinsable
  • Exact replacement of HP-210
  • Close equivalent to USP Phase G6

Similar Phases: SP-2401

DB-225

  • (50%-Cyanopropylphenyl)-dimethylpolysiloxane
  • Mid/high polarity
  • Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs)
  • Bonded and cross-linked
  • Solvent rinsable
  • Exact replacement of HP-225
  • Close equivalent to USP Phase G7

Similar Phases: SP-2330, Rtx-225, BP-225, OV-225, 007-225, AT-225

CP-Sil 43 CB

  • 25% Cyanopropyl/25% phenyl/50% dimethylpolysiloxane phase
  • Mid polarity
  • Separates aromatic from aliphatic hydrocarbons with selectivity equivalent to OV-255
  • Bonded and cross-linked
  • Solvent rinsable
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: SP-2330, Rtx-225, BP-225, OV-225, 007-225, AT-225

DB-1301

  • (6%-Cyanopropyl-phenyl) methylpolysiloxane
  • Equivalent to USP Phase G43
  • Low/mid polarity
  • Bonded and cross-linked
  • Exact replacement of HP-1301 and HP-1701
  • Solvent rinsable

Similar Phases: Rtx-1301, PE-1301

CP-1301

  • 6% Cyanopropyl-phenyl/94% dimethylpolysiloxane
  • Mid polarity
  • Ideal for analysis of herbicides, pesticides and many pharmaceutical products
  • High column-to-column reproducibility
  • Good inertness for better quality of data, even with thick films
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation
  • Bonded and cross-linked
  • Solvent rinsable

Similar Phases: Rtx-1301, PE-1301

DB-1701

  • (14% Cyanopropyl-phenyl)-methylpolysiloxane
  • Low/mid polarity
  • Bonded and cross-linked
  • Exact replacement of HP-1301 and HP-1701
  • Solvent rinsable

Similar Phases: SPB-1701, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-1701

CP-sil 19 CB

  • 14% Cyanopropyl-phenyl/86% dimethylpolysiloxane
  • Mid polarity
  • Ideal for many environmental, food and beverage, and pharmaceutical applications
  • Useful as confirmation column
  • Bonded and cross-linked
  • Solvent rinsable
  • Broad range of configurations available
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

Similar Phases: SPB-1701, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-1701

Polyethylene Glycol (PEG) Columns

Agilent offers a full range of PEG columns. Even though each phase is based on the polyethylene glycol polymer, strict control of the cross-linking and deactivation processes result in a variety of unique phase characteristics to meet your varying analysis needs.

DB-WAX and DB-WaxFF

  • Polyethylene glycol (PEG)
  • Equivalent to USP Phase G16
  • High polarity
  • Lower temperature limit of 20 °C is the lowest of any bonded PEG phase; improves resolution of low boiling point analytes
  • Column-to-column reproducibility
  • Bonded and cross-linked
  • Exact replacement of HP-WAX
  • Solvent rinsable
  • DB-WaxFF is a highly reproducible, specially tested microbore DB-Wax for fragrance analysis

Similar Phases: SUPELCOWAX 10, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, Rtx-WAX, ZB-WAX, ZB-WAX plus

DB-WAXetr

  • Polyethylene glycol (PEG)
  • Extended temperature range (etr)
  • High polarity
  • Excellent column-to-column repeatability
  • Bonded and cross-linked
  • Solvent rinsable
  • Equivalent to USP Phase G16

Similar Phases: SUPELCOWAX 10, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, Rtx-WAX, ZB-WAX, ZB-WAX plus

HP-innoWax

  • Polyethylene glycol (PEG)
  • High polarity
  • Highest upper temperature limits of the bonded PEG phases
  • Column-to-column repeatability
  • Bonded and cross-linked
  • Solvent rinsable
  • Close equivalent to USP Phase G16

Similar Phases: SUPELCOWAX 10, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, ZB-WAX, ZB-WAX+

CP-Wax 52 CB

  • Polyethylene glycol phase
  • High polarity
  • Wider temperature range than non-bonded polyethylene glycols
  • Bonded and cross-linked
  • Solvent rinsable
  • High resolution of low boiling point analytes
  • High polarity provides separations for a broad range of applications
  • Excellent reproducibility and temperature stability for a variety of EPA and ASTM methods
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation

note:We recommend the UltiMetal column when working in rugged environments with process or portable instruments.

Similar Phases: SUPELCOWAX 10, SUPEROX II, CB-WAX, Stabilwax, BP-20, 007-CW, Carbowax, HP-INNOWax, Rtx-WAX, ZB-WAX, ZB-WAX+

DB-FFAP

  • Nitroterephthalic acid modified polyethylene glycol
  • High polarity
  • Temperature range from 40 °C to 250 °C
  • Designed for the analysis of volatile fatty acids and phenols
  • Replaces OV-351
  • Bonded and cross-linked
  • Solvent rinsable
  • Close equivalent to USP Phase G35

note: We do not recommend the use of water or methanol to rinse DB-FFAP GC columns.

Similar Phases: Stabilwax-DA, Nukol, 007-FFAP, BP21, AT-1000, OV-351

HP-FFAP

  • Nitroterephthalic acid modified polyethylene glycol
  • High polarity
  • Temperature range from 60 °C to 240/250 °C (230/240 °C for 0.53 mm)
  • Designed for the analysis of volatile fatty acids and phenols
  • Replaces OV-351
  • Bonded and cross-linked
  • Solvent rinsable
  • Close equivalent to USP Phase G35

Note: We do not recommend the use of water or methanol to rinse HP-FFAP GC columns.

Similar Phases: Stabilwax-DA, Nukol, 007-FFAP, BP21, AT-1000, OV-351

Life Sciences Columns

The life sciences offer some difficult challenges to capillary GC chromatographers. These include complex sample matrixes, the necessity for low level detection and the chemically active characteristics of many of the samples. In response to this, Agilent offers a line of columns which are designed specifically for drugs of abuse testing.

DB-AlC1 and DB-AlC2

  • Reliable blood alcohol analysis
  • Optimized primary and confirmation column pair for US blood alcohol analysis
  • DB-ALC1 and DB-ALC2 columns are regularly used in sets. Connect them together easily with an Agilent Ultra Inert, universal press fit Y-splitter (5190-6980), or an UltiMetal Plus deactivated CFT un-purged splitter (G3184-60065)
  • Faster GC run times
  • Improved resolution of key ethanol/acetone peaks
  • Available in 0.32 and 0.53 mm id
  • Bonded and cross-linked

Similar phases: Rtx-BAC1, Rtx-BAC2, ZB-BAC-1, ZB-BAC-2

Others

PloT Columns

PLOT columns are ideal for separating compounds that are gases at room temperatures. Agilent Technologies offers a comprehensive line of PLOT columns for analysis of fixed gases, low molecular weight hydrocarbon isomers, volatile polar compounds and reactive analytes such as sulfur gases, amines and hydrides. Our PLOT phases are offered in dimensions from 0.25 to 0.53 mm id, allowing for easy column selection for various detector and system requirements. For GC/MS systems, we offer several small diameter columns with truly bonded and immobilized stationary phases, eliminating potential detector fouling due to particle generation.

PloT PT

Agilent J&W PLOT PT columns are engineered to improve lab operations. Unlike current techniques used to prevent PLOT stationary phase particles from shedding downstream, the integral particle traps of the PLOT PT columns remove the aggravation of connecting separate traps. Operation is more convenient and there is no risk from leaks. The integrated particle-trapping technology on both ends of PLOT PT GC columns reduces downtime. What’s more, with PLOT PT you can now use GC/MS for detailed, qualitative and quantitative analysis and due to the dual ended particle traps the PLOT PT columns can also be used for backflush applications. No other PLOT column offers this level of worry-free operation for your GC or GC/MS system. Agilent J&W PLOT PT columns are available in porous polymers Q and U, Aluminum oxide and Molesieve stationary phases.

Guard Columns

  • DuraGuard and EZ-Guard columns with “built-in” guard columns, no press-fit connectors
  • Minimize front-end contamination and increase column lifetime
  • Aid in focusing sample onto the front of the column for better peak shape
  • Minimize MSD contamination originating from the column (when used as transfer line to the MS detector)

Guard columns (or retention gaps) are often added to the front of the analytical column to protect against contamination, or to act as a band-focusing device for liquid samples introduced by on-column and splitless injection techniques.

When resolution or response in a chromatogram diminishes, remove a coil from the guard columnso that peak shapes will improve. By removing a coil, the column length is shortened and peaks will elute somewhat faster. For best results, check the integration time windows of your data system.

Brand

Agilent Technologies

Agilent is a leader in life sciences, diagnostics and applied chemical markets. The company provides laboratories worldwide with instruments, services, consumables, applications and expertise, enabling customers to gain the insights they seek. Agilent’s expertise and trusted collaboration give them the highest confidence in our solutions.

Similar Products

test block for Laos

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Your download – just a few steps away

Please enter your details here:

test

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us