ABclonal – ELISA Kits
-
THAILAND
DKSH Technology Limited (Head Office)
2533 Sukhumvit Road, Bangchak, Phrakhanong
10260 Bangkok
Thailand
Human IL-1 beta Brochure
Human IL-6 Brochure
Mouse IL-1 beta Brochure
Mouse IL-6 Brochure
Human IFN-gamma Brochure
Mouse IL-10 Brochure
Mouse TNF-alpha Brochure
Human TNF-alpha Brochure
Mouse Transforming Growth Factor Beta 1ELISAKit(TGFb1) Brochure
Available Models
Technical Specifications
Sample type | Serum, plasma and cell culture supernates | |
---|---|---|
Cross reacts with | Human | |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. | |
Sensitivity | 3.9 pg/mL | |
Standard curve range | 6.25-400 pg/ml | |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution | |
1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations. 2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. |
This Human IL-1 beta ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. Calibration standards are included, allowing you to create a standard curve to determine sample concentrations by comparing their O.D. to the curve.
Technical Specifications
Sample type | Serum, plasma and cell culture supernates | |
---|---|---|
Cross reacts with | Human | |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. | |
Sensitivity | 0.7 pg/mL | |
Standard curve range | 1.56-100pg/ml | |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution | |
1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations. 2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. |
This Human IL-6 ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. Calibration standards are included, enabling the creation of a standard curve for sample concentration determination by comparing their O.D. to the curve.
Technical Specifications
Sample type | Serum, plasma and cell culture supernates | |
---|---|---|
Cross reacts with | Mouse | |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. | |
Sensitivity | 7.8 pg/mL | |
Standard curve range | 15.6-1000 pg/ml | |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution | |
1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations. 2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. |
This Mouse IL-1 beta ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. Included calibration standards enable the creation of a standard curve to determine Mouse IL-1 beta concentration by comparing sample O.D. to the curve.
Technical Specifications
Sample type | serum, plasma, cell culture supernatants, cell Lysates, tissue homogenates and other biological fluids. | |
---|---|---|
Cross reacts with | Mouse | |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. | |
Sensitivity | 7.2 pg/mL | |
Standard curve range | 15.6-1000 pg/ml | |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution | |
1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations. 2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. |
This Mouse IL-6 ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.
Technical Specifications
Sample type | serum, plasma, cell culture supernates |
---|---|
Cross reacts with | Human |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. |
Sensitivity | 7.3 pg/mL |
Standard curve range | 15.6-1000 pg/ml |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution |
This Human IFN-gamma ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm using a spectrophotometer. Calibration standards included enable the creation of an optical density standard curve for determining Human IFN-gamma concentration by comparing sample O.D. to the curve.
Technical Specifications
Sample type | serum, plasma, cell culture supernates |
---|---|
Cross reacts with | Mouse |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. |
Sensitivity | 15.6 pg/mL |
Standard curve range | 31.2-2000 pg/mL |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution |
This Mouse IL-10 ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.
Technical Specifications
Sample type | serum, plasma, cell culture supernates |
---|---|
Cross reacts with | Mouse |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. |
Sensitivity | 6.5 pg/mL |
Standard curve range | 15.6-1000 pg/mL |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution |
This Mouse TNF-alpha ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.
Technical Specifications
Sample type | serum, plasma, cell culture supernates | |
---|---|---|
Cross reacts with | Human | |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. | |
Sensitivity | 6.9 pg/mL | |
Standard curve range | 15.6-1000 pg/ml | |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution | |
1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations. 2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. |
This Human TNF-alpha ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.
Technical Specifications
Sample type | serum, plasma, cell culture supernates | |
---|---|---|
Cross reacts with | Mouse | |
Storage instructions | Unopened kits can be stored at 2-8°C for 1 year, and opened products must be used within 1 month. | |
Sensitivity | 3.9 pg/mL | |
Standard curve range | 15.6-1000 pg/ml | |
Components | Microtiter Plate Enzyme Conjugate Standards Substrate A Substrate B Stop Solution Wash Solution Balance Solution | |
1. This kit contains a small amount of sodium azide, which can react with plumbing materials to form explosive compounds. When disposing of it, flush drains with ample water to prevent buildup. Avoid contact with eyes, skin, or ingestion. In case of contact, rinse thoroughly with water and follow local disposal regulations. 2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. |
This Mouse Transforming Growth Factor Beta 1 (TGFb1) ELISA kit is for research use only, not for diagnostics or therapy. The stop solution changes color, measured at 450 nm with a spectrophotometer. It includes calibration standards for creating an optical density standard curve to determine Mouse IL-6 concentration by comparing sample O.D. to the curve.
Brand
Based in Massachusetts, ABclonal aims to improve the accuracy and precision of life science research for scientists around the world by providing high-quality, personalized biology research reagents and services. Our large catalog of off-the-shelf products can be customized to ensure you can have the antibodies, peptides, and proteins best suited to you.
Similar Products
Download now