Metrohm – NIRS XDS – Transmission Optiprobe Analyzer

The NIRS XDS Transmission OptiProbe Analyzer enables efficient determination of the composition of aqueous products, clear liquids, solvents and viscous samples. The instrument is equally suitable for use in technical centers or for at-line applications in the context of scale-ups of production processes. 

Inquiry Now

Overview

Features

Specifications

NIRS disposable glass vials are available for viscous samples, limiting cleaning costs to a minimum. The optionally available NIRS Vial Heater can be used to analyze samples at a temperature of up to 200 °C.

Technical Specifications

Measuring modeTransmission
Sample interfaceDirect analysis
Wavelength range400–2,500 nm
Measuring moduleHot-swappable
DetectorsSilicon (400–1,100 nm), lead sulfide (1,100–2,500 nm)
Data collection speed2 scans/s
Data point interval0.5 nm
Wavelength accuracy
(currently recognized standard)
< 0.08 nm
Wavelength precision1< 0.008 nm
Wavelength precision2 (instrument to instrument)< 0.025 nm
Stray light< 0.1% at 2,300 nm
Photometric linearity< 1% of the measured value
Bandpass8.75 ±0.10 nm
Noise (RMS)400–700 nm < 80 micro AU
700–2,200 nm < 30 micro AU
Weight34.0 kg (74.0 lbs)
Dimensions (W × H × D)455 × 346 × 559 mm (17.9″ × 13.6″ × 22″)
Operating temperature range4.5–35°C (40–95°F)
Relative humidity10–90% RH, non-condensing

Key Features

NIRS XDS Transmission OptiProbe Analyzer

  • Self-stabilizing NIRS XDS VialHeater with 9 positions (can be heated up to 200°C)
  • NIRS disposable glass vials for analyzing viscous samples
  • Network-compatible – central result and data management (client-server solution)
  • Universal interface for quickly changing the measuring modules in just seconds

NIRSystems XDS Analyzers – Pharmaceutical Testing

Key Industries

  • Chemical
  • Cosmetics & Personal Care
  • Oil & Gas
  • Polymers, Plastics and Rubbers
  • Powders & Pigments / Coating

More Products

Metrohm

Founded in 1943 by the engineer Bertold Suhner, Metrohm is one of the world’s leading maker of instruments for chemical…

  • Brochure: NIRS XDS Transmission OptiProbe Analyzer – Robust measurement system for reaction monitoring of liquids in technical centers and pilot plant stations


  • MYANMAR

    DKSH (Myanmar) Ltd. Thitsar Road, Yankin Township Yangon Myanmar

    +951 8565270

    Contact Now

  • PHILIPPINES

    DKSH Philippines Inc. 8th Floor Cyber Sigma, Lawton Ave., McKinley West, Fort Bonifacio 1634 Taguig City Philippines

    +63 2 8548 3200

    Contact Now

Delivering Growth – in Asia and Beyond

Follow Us

© DKSH International Ltd.  All Rights Reserved.

test block for Laos

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Your download – just a few steps away

Please enter your details here:

test

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us

Contact us